"Dhibiti kiwango kwa maelezo, onyesha nishati kwa ubora".Biashara yetu imejitahidi kuanzisha wafanyakazi wenye ufanisi mkubwa na thabiti na kuchunguza utaratibu mzuri wa udhibiti wa ubora wa jumla wa Kiwanda Yanayofaa kwa Hoteli, Hospitali ya DIN Rail AC Contactor (WCTS-16/20), Tunajitahidi kwa dhati kutoa huduma bora kwa watumiaji wengi na wafanyabiashara.
"Dhibiti kiwango kwa maelezo, onyesha nishati kwa ubora".Biashara yetu imejitahidi kuanzisha wafanyakazi wenye ufanisi mkubwa na thabiti na kuchunguza utaratibu mzuri wa udhibiti wa ubora waChina DIN Rail AC Contactor na Kaya Contactor, Kuna vifaa vya juu vya uzalishaji na usindikaji na wafanyikazi wenye ujuzi ili kuhakikisha bidhaa na ubora wa juu.Sasa tumepata huduma bora kabla ya kuuza, kuuza, baada ya kuuza ili kuhakikisha wateja ambao wanaweza kuwa na uhakika wa kuagiza.Hadi sasa bidhaa zetu sasa zinaendelea kwa kasi na maarufu sana katika Amerika ya Kusini, Asia ya Mashariki, Mashariki ya Kati, Afrika, nk.
Kiunganishaji cha AC cha mfululizo wa RDC5 kina viwango 4 vya sasa vya makazi, sasa ya hiari ni kutoka 6A hadi 95A, na mfululizo huo huongeza mikondo miwili mipya (06A na 38A_ ikilinganishwa na CJX2 ili kukidhi mahitaji tofauti ya usambazaji wa nishati.
Bidhaa hiyo imepitisha uidhinishaji wa kitaifa wa 3C, inachukua uongozi wa bidhaa zinazofanana kwenye tasnia na inahakikisha utendakazi salama na thabiti wa mfumo wa usambazaji wa nishati.
1. Ubora wa juu, kuhimili uchambuzi
2. Masafa ya kuvuta-katika voltage yenye nguvu zaidi
3. Utendaji bora na maisha ya muda mrefu
4. Ubunifu wa kibinadamu na ufungaji rahisi
5. Athari kamili ya kuzuia vumbi, wigo mpana wa matumizi
6. Kusaidia vifaa na ufungaji
Kuwa jukwaa la wafanyikazi kutimiza ndoto zao!Unda timu yenye furaha zaidi, umoja na taaluma zaidi!Tunakaribisha kwa dhati wanunuzi wa kigeni kushauriana kwa ushirikiano wa muda mrefu na maendeleo ya pande zote.
Kwa bei isiyobadilika ya ushindani, tumezingatia mageuzi ya suluhisho kila wakati, tumewekeza mtaji na rasilimali watu nyingi katika kuboresha teknolojia, kukuza uboreshaji wa uzalishaji, na kukidhi mahitaji ya nchi na maeneo yote.
Timu yetu ina uzoefu tajiri wa tasnia na kiwango cha juu cha kiufundi.80% ya wanachama wa timu wana zaidi ya miaka 5 ya uzoefu wa huduma ya kiufundi wa bidhaa.Kwa hivyo, tuna uhakika sana kukupa ubora na huduma bora.Kwa miaka mingi, kampuni imesifiwa na kuthaminiwa na wateja wapya na wa zamani kwa madhumuni yake ya "huduma ya hali ya juu na kamilifu""Dhibiti kiwango kwa maelezo, onyesha nishati kwa ubora." Biashara yetu imejitahidi kuanzisha wafanyakazi wenye ufanisi mkubwa na thabiti na kugundua utaratibu mzuri wa udhibiti wa ubora wa jumla wa Kiwanda Inafaa kwa Hoteli, Hospitali DIN Rail AC Contactor (WCTS-16/20), Tunafanya kwa dhati tuwezavyo kutoa huduma bora kwa watumiaji wengi na wafanyabiashara.
Uuzaji wa jumla wa kiwandaChina DIN Rail AC Contactor na Kaya Contactor, Kuna vifaa vya juu vya uzalishaji na usindikaji na wafanyikazi wenye ujuzi ili kuhakikisha bidhaa na ubora wa juu.Sasa tumepata huduma bora kabla ya kuuza, kuuza, baada ya kuuza ili kuhakikisha wateja ambao wanaweza kuwa na uhakika wa kuagiza.Hadi sasa bidhaa zetu sasa zinaendelea kwa kasi na maarufu sana katika Amerika ya Kusini, Asia ya Mashariki, Mashariki ya Kati, Afrika, nk.
Swichi ni moja ya vifaa muhimu vya umeme nyumbani na mahali pa biashara.Swichi za ubora wa juu haziwezi tu kutoa udhibiti rahisi wa umeme, lakini pia kuhakikisha usalama wa watumiaji.Bidhaa zetu zina sifa zifuatazo:
1. Vifaa vya kuhami vya ubora wa juu: swichi za ubora wa juu kawaida hutumia vifaa vya kuhami vya juu, ambavyo vinaweza kutenganisha kwa ufanisi sasa, kuzuia uvujaji wa sasa na kuhakikisha usalama wa kibinafsi wa watumiaji.Ikilinganishwa na swichi za ubora wa chini, swichi za ubora wa juu zina maisha marefu ya huduma na zinaweza kuhimili vyema majaribio ya muda na matumizi.
2. Ufungaji rahisi na uendeshaji rahisi: swichi za ubora wa juu ni kawaida rahisi katika kubuni na rahisi kufunga.Hata bila msaada wa wataalamu wa umeme, watumiaji wanaweza kukamilisha ufungaji kwa urahisi.Kwa kuongeza, swichi hizi pia ni rahisi sana kufanya kazi.Watumiaji wanaweza kudhibiti swichi za vifaa vya umeme kwa urahisi bila hofu ya hatari.
3. Hatua nyingi za ulinzi wa usalama: swichi za ubora wa juu kawaida huwa na hatua nyingi za ulinzi, kama vile ulinzi dhidi ya upakiaji, mzunguko mfupi, kuvuja na kazi zingine za usalama.Hatua hizi za kinga zinaweza kuepuka hatari inayosababishwa na uharibifu wa ajali wa vifaa vya umeme na kulinda usalama wa watumiaji na vifaa vya umeme yenyewe.
4. Uidhinishaji ulioidhinishwa na wa hali ya juu: swichi za ubora wa juu kwa kawaida huidhinishwa na mamlaka mbalimbali, kama vile uidhinishaji wa CE, uidhinishaji wa UL, n.k. Vyeti hivi vinathibitisha kuwa swichi hiyo inatii viwango vya usalama vya kimataifa na ina utiifu wa hali ya juu.Kutumia swichi hizi zilizoidhinishwa kunaweza kusaidia watumiaji kupunguza hatari na kupata hali ya matumizi salama.
Masafa ya 70% -120% Us ya kuvuta voltage
Izidi bidhaa zinazofanana 20%
RDC5 ina vituo vya nyaya vya juu na chini ili mtumiaji aweze kuunganisha waya kwa haraka na kwa usalama zaidi.
Athari kamili ya kuzuia vumbi, inayotumika kwa mazingira anuwai ya kufanya kazi.
Mfano wa Bidhaa | RDC5-06 | RDC5-09 | RDC5-12 | RDC5-18 | RDC5-25 | RDC5-32 | RDC5-38 | RDC5-40 | RDC5-50 | RDC5-65 | RDC5-80 | RDC5-95
| ||||||||||||||||||||||||||||||||||||||
Idadi ya pole |
3 nguzo | |||||||||||||||||||||||||||||||||||||||||||||||||
Uhamishaji uliokadiriwa Voltage(Ui)V |
690
| |||||||||||||||||||||||||||||||||||||||||||||||||
Ilipimwa voltage ya uendeshaji(Ue)V | 380/400, 660/690 | |||||||||||||||||||||||||||||||||||||||||||||||||
Mkondo wa kupokanzwa wa kawaida(Ith)A | 16 | 20 | 20 | 25 | 32 | 40 | 40 | 50 | 60 | 80 | 110 |
110
| ||||||||||||||||||||||||||||||||||||||
Iliyokadiriwa sasa (le)A | AC-3 | 380/400V | 6 | 9 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 | ||||||||||||||||||||||||||||||||||||
660/690V | 3.8 | 6.6 | 8.9 | 12 | 18 | 22 | 22 | 34 | 39 | 42 | 49 | 49 | ||||||||||||||||||||||||||||||||||||||
AC-4 | 380/400V | 2.6 | 3.5 | 5 | 7.7 | 8.5 | 12 | 14 | 18.5 | 24 | 28 | 37 | 44 | |||||||||||||||||||||||||||||||||||||
660/690V | 1 | 1.5 | 2 | 3.8 | 4.4 | 7.5 | 8.9 | 9 | 12 | 14 | 17.3 | 21.3 | ||||||||||||||||||||||||||||||||||||||
Nguvu Iliyokadiriwa (PE)KW | AC-3 | 380/400V | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 18.5 | 22 | 30 | 37 | 45 | ||||||||||||||||||||||||||||||||||||
660/690V | 3 | 5.5 | 7.5 | 10 | 15 | 18.8 | 18.5 | 30 | 33 | 37 | 45 | 45 | ||||||||||||||||||||||||||||||||||||||
AC-4 | 380/400V | 1.1 | 1.5 | 2.2 | 3.3 | 4 | 5.4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |||||||||||||||||||||||||||||||||||||
660/690V | 0.75 | 1.1 | 1.5 | 3 | 3.7 | 5.5 | 6 | 7.5 | 10 | 11 | 15 | 18.5 | ||||||||||||||||||||||||||||||||||||||
Maisha ya mitambo (mara 10000 kwa saa) | 1200 | 1000 | 900 | 650 | ||||||||||||||||||||||||||||||||||||||||||||||
Maisha ya umeme | AC-3(mara 10000/saa) | 110 | 90 | 65 | ||||||||||||||||||||||||||||||||||||||||||||||
AC-4(mara 10000/saa) | 22 | 22 | 17 | 11 | ||||||||||||||||||||||||||||||||||||||||||||||
Mzunguko wa operesheni | AC-3(nyakati/saa) | 1200 | 600 | |||||||||||||||||||||||||||||||||||||||||||||||
AC-4(nyakati/saa) | 300 | |||||||||||||||||||||||||||||||||||||||||||||||||
Koili | Voltage adimu ya kudhibiti Us(V) | AC 24,36,48,110,127,220/230,240,380/400,415,440 | ||||||||||||||||||||||||||||||||||||||||||||||||
Voltage ya kuingiza 50/60HZ V | (0.85-1.1)Sisi | |||||||||||||||||||||||||||||||||||||||||||||||||
Kutoa voltage 50/60Hz V | (0.2-0.7)Sisi | |||||||||||||||||||||||||||||||||||||||||||||||||
Chaguo la matumizi ya nguvu ya coil | Vuta-ndani VA | 50 | 60 | 70 | 200 | 200 | ||||||||||||||||||||||||||||||||||||||||||||
Shikilia VA | 6-9 | 6-9.5 | 6-9.5 | 15-20 | 15-20 | |||||||||||||||||||||||||||||||||||||||||||||
Nguvu W | 1-3 | 1-3 | 1-3 | 6-10 | 6-10 | |||||||||||||||||||||||||||||||||||||||||||||
Vipande mm² | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | ||||||||||||||||||||||||||
Vituo | Waya inayonyumbulika na terminal mm² | 4 | 2.5 | 4 | 2.5 | 4 | 2.5 | 4 | 2.5 | 6 | 4 | 6 | 4 | 6 | 4 | 25 | 10 | 25 | 10 | 25 | 10 | 50 | 16 | 50 | 16 | |||||||||||||||||||||||||
Waya inayonyumbulika bila terminal mm² | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 6 | 6 | 6 | 6 | 25 | 16 | 25 | 16 | 25 | 16 | 50 | 25 | 50 | 25 | ||||||||||||||||||||||||||
Waya ngumu mm² | 4 | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 6 | 6 | 10 | 6 | 10 | 6 | 25 | 10 | 25 | 10 | 25 | 10 | 50 | 25 | 50 | 25 | ||||||||||||||||||||||||||
Torque ya kukaza | (N*m) | 1.2 | 1.8 | 5 | 9 | |||||||||||||||||||||||||||||||||||||||||||||
Aina ya fuse inayofaa | Mfano | RDT16(NT)-00 | ||||||||||||||||||||||||||||||||||||||||||||||||
Iliyokadiriwa sasa(A) | 16 | 20 | 20 | 32 | 40 | 50 | 63 | 63 | 80 | 80 | 100 |
125
| ||||||||||||||||||||||||||||||||||||||
Relay inayofaa ya joto | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 RDR5-36 | RDR5-25 RDR5-36 | RDR5-93 | RDR5-93 | RDR5-93 | RDR5-93 | RDR5-93 | ||||||||||||||||||||||||||||||||||||||
Wawasiliani wasaidizi | Inaweza kuongezwa kwa anwani za F4,LA8, anwani za kuchelewesha hewa za aina ya LA-D/LA3-D |
Mfano | Amax | Bmax | B1 kiwango cha juu | B2 juu | Cmax | C1 upeo | C2 upeo | ||||||
RDC5-06,09,12,18 | 74.5 | 45.5 | 58 | 71 | 82.5 | 114.5 | 139.5 | ||||||
RDC5-25,32,38 | 83 | 56.5 | 69 | 82 | 97 | 129 | 154 | ||||||
RDC5-40,50,65 | 127.5 | 74.5 | 88 | 101 | 117 | 148.5 | 173.5 | ||||||
RDC5-80.95 | 127.5 | 85.5 | 99 | 112 | 125.5 | 157 | 182 | ||||||
Kumbuka: | B1max=contactor+LA8;B2max=contactor+2×LA8;C1max=contactor+F4;C2max=contactor+LA2(3)D |
Mfano | a | b | c | d | e | f | ||||||
RDC5-06,09,12,18 | 35 | 50/60 | - | - | - | - | ||||||
RDC5-25,32,38 | 40 | 50/60 | - | - | - | - | ||||||
RDC5-40,50,65 | - | - | 105 | 40 | 100/110 | 59 | ||||||
RDC5-80.95 | - | - | 105 | 40 | 100/110 | 67 |
Hali ya kawaida ya uendeshaji na hali ya ufungaji
3.1Joto la Mazingira:+5℃~+40℃joto la averaae ndani ya saa 24 halizidi+35℃
3.2 Mwinuko:hauzidi2000m
3.3 Hali ya angahewa: wakati halijoto ya juu zaidi ni +40℃unyevunyevu kiasi hauzidi 50%; inaweza kuruhusu unyevunyevu wa juu kiasi wakati iko kwenye joto la chini kiasi, kwa
mfano.inafikia 90% wakati iko +20 inapaswa kuchukua kipimo wakati kuna
condensation ilitokea kutokana na tofauti ya joto.
3.4 Kiwango cha uchafuzi wa mazingira:3
3.5Kategoria ya usakinishaji:l
3.6 Nafasi ya usakinishaji: mwangaza wa uso wa mlima hadi uso wima hauzidi +5°
3.7lmpact na vibration: bidhaa inapaswa kusakinishwa na kutumika katika maeneo bila athari dhahiri ya mtikiso na vibration.
Swichi ni moja ya vifaa muhimu vya umeme nyumbani na mahali pa biashara.Swichi za ubora wa juu haziwezi tu kutoa udhibiti rahisi wa umeme, lakini pia kuhakikisha usalama wa watumiaji.Bidhaa zetu zina sifa zifuatazo:
1. Vifaa vya kuhami vya ubora wa juu: swichi za ubora wa juu kawaida hutumia vifaa vya kuhami vya juu, ambavyo vinaweza kutenganisha kwa ufanisi sasa, kuzuia uvujaji wa sasa na kuhakikisha usalama wa kibinafsi wa watumiaji.Ikilinganishwa na swichi za ubora wa chini, swichi za ubora wa juu zina maisha marefu ya huduma na zinaweza kuhimili vyema majaribio ya muda na matumizi.
2. Ufungaji rahisi na uendeshaji rahisi: swichi za ubora wa juu ni kawaida rahisi katika kubuni na rahisi kufunga.Hata bila msaada wa wataalamu wa umeme, watumiaji wanaweza kukamilisha ufungaji kwa urahisi.Kwa kuongeza, swichi hizi pia ni rahisi sana kufanya kazi.Watumiaji wanaweza kudhibiti swichi za vifaa vya umeme kwa urahisi bila hofu ya hatari.
3. Hatua nyingi za ulinzi wa usalama: swichi za ubora wa juu kawaida huwa na hatua nyingi za ulinzi, kama vile ulinzi dhidi ya upakiaji, mzunguko mfupi, kuvuja na kazi zingine za usalama.Hatua hizi za kinga zinaweza kuepuka hatari inayosababishwa na uharibifu wa ajali wa vifaa vya umeme na kulinda usalama wa watumiaji na vifaa vya umeme yenyewe.
4. Uidhinishaji ulioidhinishwa na wa hali ya juu: swichi za ubora wa juu kwa kawaida huidhinishwa na mamlaka mbalimbali, kama vile uidhinishaji wa CE, uidhinishaji wa UL, n.k. Vyeti hivi vinathibitisha kuwa swichi hiyo inatii viwango vya usalama vya kimataifa na ina utiifu wa hali ya juu.Kutumia swichi hizi zilizoidhinishwa kunaweza kusaidia watumiaji kupunguza hatari na kupata hali ya matumizi salama.
Masafa ya 70% -120% Us ya kuvuta voltage
Izidi bidhaa zinazofanana 20%
RDC5 ina vituo vya nyaya vya juu na chini ili mtumiaji aweze kuunganisha waya kwa haraka na kwa usalama zaidi.
Athari kamili ya kuzuia vumbi, inayotumika kwa mazingira anuwai ya kufanya kazi.
Mfano wa Bidhaa | RDC5-06 | RDC5-09 | RDC5-12 | RDC5-18 | RDC5-25 | RDC5-32 | RDC5-38 | RDC5-40 | RDC5-50 | RDC5-65 | RDC5-80 | RDC5-95
| ||||||||||||||||||||||||||||||||||||||
Idadi ya pole |
3 nguzo | |||||||||||||||||||||||||||||||||||||||||||||||||
Uhamishaji uliokadiriwa Voltage(Ui)V |
690
| |||||||||||||||||||||||||||||||||||||||||||||||||
Ilipimwa voltage ya uendeshaji(Ue)V | 380/400, 660/690 | |||||||||||||||||||||||||||||||||||||||||||||||||
Mkondo wa kupokanzwa wa kawaida(Ith)A | 16 | 20 | 20 | 25 | 32 | 40 | 40 | 50 | 60 | 80 | 110 |
110
| ||||||||||||||||||||||||||||||||||||||
Iliyokadiriwa sasa (le)A | AC-3 | 380/400V | 6 | 9 | 12 | 18 | 25 | 32 | 38 | 40 | 50 | 65 | 80 | 95 | ||||||||||||||||||||||||||||||||||||
660/690V | 3.8 | 6.6 | 8.9 | 12 | 18 | 22 | 22 | 34 | 39 | 42 | 49 | 49 | ||||||||||||||||||||||||||||||||||||||
AC-4 | 380/400V | 2.6 | 3.5 | 5 | 7.7 | 8.5 | 12 | 14 | 18.5 | 24 | 28 | 37 | 44 | |||||||||||||||||||||||||||||||||||||
660/690V | 1 | 1.5 | 2 | 3.8 | 4.4 | 7.5 | 8.9 | 9 | 12 | 14 | 17.3 | 21.3 | ||||||||||||||||||||||||||||||||||||||
Nguvu Iliyokadiriwa (PE)KW | AC-3 | 380/400V | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 18.5 | 22 | 30 | 37 | 45 | ||||||||||||||||||||||||||||||||||||
660/690V | 3 | 5.5 | 7.5 | 10 | 15 | 18.8 | 18.5 | 30 | 33 | 37 | 45 | 45 | ||||||||||||||||||||||||||||||||||||||
AC-4 | 380/400V | 1.1 | 1.5 | 2.2 | 3.3 | 4 | 5.4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |||||||||||||||||||||||||||||||||||||
660/690V | 0.75 | 1.1 | 1.5 | 3 | 3.7 | 5.5 | 6 | 7.5 | 10 | 11 | 15 | 18.5 | ||||||||||||||||||||||||||||||||||||||
Maisha ya mitambo (mara 10000 kwa saa) | 1200 | 1000 | 900 | 650 | ||||||||||||||||||||||||||||||||||||||||||||||
Maisha ya umeme | AC-3(mara 10000/saa) | 110 | 90 | 65 | ||||||||||||||||||||||||||||||||||||||||||||||
AC-4(mara 10000/saa) | 22 | 22 | 17 | 11 | ||||||||||||||||||||||||||||||||||||||||||||||
Mzunguko wa operesheni | AC-3(nyakati/saa) | 1200 | 600 | |||||||||||||||||||||||||||||||||||||||||||||||
AC-4(nyakati/saa) | 300 | |||||||||||||||||||||||||||||||||||||||||||||||||
Koili | Voltage adimu ya kudhibiti Us(V) | AC 24,36,48,110,127,220/230,240,380/400,415,440 | ||||||||||||||||||||||||||||||||||||||||||||||||
Voltage ya kuingiza 50/60HZ V | (0.85-1.1)Sisi | |||||||||||||||||||||||||||||||||||||||||||||||||
Kutoa voltage 50/60Hz V | (0.2-0.7)Sisi | |||||||||||||||||||||||||||||||||||||||||||||||||
Chaguo la matumizi ya nguvu ya coil | Vuta-ndani VA | 50 | 60 | 70 | 200 | 200 | ||||||||||||||||||||||||||||||||||||||||||||
Shikilia VA | 6-9 | 6-9.5 | 6-9.5 | 15-20 | 15-20 | |||||||||||||||||||||||||||||||||||||||||||||
Nguvu W | 1-3 | 1-3 | 1-3 | 6-10 | 6-10 | |||||||||||||||||||||||||||||||||||||||||||||
Vipande mm² | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | ||||||||||||||||||||||||||
Vituo | Waya inayonyumbulika na terminal mm² | 4 | 2.5 | 4 | 2.5 | 4 | 2.5 | 4 | 2.5 | 6 | 4 | 6 | 4 | 6 | 4 | 25 | 10 | 25 | 10 | 25 | 10 | 50 | 16 | 50 | 16 | |||||||||||||||||||||||||
Waya inayonyumbulika bila terminal mm² | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 6 | 6 | 6 | 6 | 25 | 16 | 25 | 16 | 25 | 16 | 50 | 25 | 50 | 25 | ||||||||||||||||||||||||||
Waya ngumu mm² | 4 | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 6 | 6 | 10 | 6 | 10 | 6 | 25 | 10 | 25 | 10 | 25 | 10 | 50 | 25 | 50 | 25 | ||||||||||||||||||||||||||
Torque ya kukaza | (N*m) | 1.2 | 1.8 | 5 | 9 | |||||||||||||||||||||||||||||||||||||||||||||
Aina ya fuse inayofaa | Mfano | RDT16(NT)-00 | ||||||||||||||||||||||||||||||||||||||||||||||||
Iliyokadiriwa sasa(A) | 16 | 20 | 20 | 32 | 40 | 50 | 63 | 63 | 80 | 80 | 100 |
125
| ||||||||||||||||||||||||||||||||||||||
Relay inayofaa ya joto | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 | RDR5-25 RDR5-36 | RDR5-25 RDR5-36 | RDR5-93 | RDR5-93 | RDR5-93 | RDR5-93 | RDR5-93 | ||||||||||||||||||||||||||||||||||||||
Wawasiliani wasaidizi | Inaweza kuongezwa kwa anwani za F4,LA8, anwani za kuchelewesha hewa za aina ya LA-D/LA3-D |
Mfano | Amax | Bmax | B1 kiwango cha juu | B2 juu | Cmax | C1 upeo | C2 upeo | ||||||
RDC5-06,09,12,18 | 74.5 | 45.5 | 58 | 71 | 82.5 | 114.5 | 139.5 | ||||||
RDC5-25,32,38 | 83 | 56.5 | 69 | 82 | 97 | 129 | 154 | ||||||
RDC5-40,50,65 | 127.5 | 74.5 | 88 | 101 | 117 | 148.5 | 173.5 | ||||||
RDC5-80.95 | 127.5 | 85.5 | 99 | 112 | 125.5 | 157 | 182 | ||||||
Kumbuka: | B1max=contactor+LA8;B2max=contactor+2×LA8;C1max=contactor+F4;C2max=contactor+LA2(3)D |
Mfano | a | b | c | d | e | f | ||||||
RDC5-06,09,12,18 | 35 | 50/60 | - | - | - | - | ||||||
RDC5-25,32,38 | 40 | 50/60 | - | - | - | - | ||||||
RDC5-40,50,65 | - | - | 105 | 40 | 100/110 | 59 | ||||||
RDC5-80.95 | - | - | 105 | 40 | 100/110 | 67 |
Hali ya kawaida ya uendeshaji na hali ya ufungaji
3.1Joto la Mazingira:+5℃~+40℃joto la averaae ndani ya saa 24 halizidi+35℃
3.2 Mwinuko:hauzidi2000m
3.3 Hali ya angahewa: wakati halijoto ya juu zaidi ni +40℃unyevunyevu kiasi hauzidi 50%; inaweza kuruhusu unyevunyevu wa juu kiasi wakati iko kwenye joto la chini kiasi, kwa
mfano.inafikia 90% wakati iko +20 inapaswa kuchukua kipimo wakati kuna
condensation ilitokea kutokana na tofauti ya joto.
3.4 Kiwango cha uchafuzi wa mazingira:3
3.5Kategoria ya usakinishaji:l
3.6 Nafasi ya usakinishaji: mwangaza wa uso wa mlima hadi uso wima hauzidi +5°
3.7lmpact na vibration: bidhaa inapaswa kusakinishwa na kutumika katika maeneo bila athari dhahiri ya mtikiso na vibration.